Professional RIGrunner 4008 for 48V

Special Model for 48V (55.2 volts nominal, fully usable from 36 to 72 volts). Violet/Black Powerpoles differentiate the special voltage.The most convenient and safest way to connect all your equipment to a power source. More Description
$150.00
SKU: PRO-4008-P48
Availability: In Stock

Quantity: 

Add to cart

Customer Reviews
Be the first to review this product.
Write a Review
Related Products
6 ft. 10 gauge Power Supply Cable with 45 amp Powerpoles
6 ft. 10 gauge Power Supply Cable with 45 amp Powerpoles
Power Supply Cable - 6 feet of 10 gauge Red/Black Zip Cord mounted with 45 amp Powerpole connectors on one end and 3/8 or 1/4 inch Gold Plated ring terminals on the other. Ideal for connecting a Power Supply or Battery to a RIGrunner.
ATC Blade Type Fuses
ATC Blade Type Fuses
ATC Blade Type Fuses available in 1, 3, 5, 7.5, 10, 15, 20, 25 & 40 Amps

More Related Products
Features
  • Description: Eight output DC power buss, Fused
  • Connection: Black is Negative (common) and VIOLET is Positive 55.2 V
  • Isolation: The case is isolated from internal circuitry, including negative circuit.
  • Connectors: Anderson PowerPoles
  • Nominal Voltage: 55.2 volts dc
  • Quiescent Current: The comparator voltmeter circuit draws 25 mA continuously
  • Current Capacity: 40 amperes input, 40 amperes total output
  • Fuses: ATA/ATC, supplied with 40 A input, 25A, 25A, 25A, 10A, 10A, 5A, 1A, 1A.
  • LED Indicators: Green is Nominal 55.2 Vdc
    Red is Over 60 Vdc
    Yellow is Under 46 Vdc
    no indication below 30 Vdc
  • Buzzer: Buzzer may Sound for Over-voltage, Under-voltage, or both
  • Buzzer Activation: As supplied, there are two jumpers installed on the internal header that activate the buzzer. With both jumpers removed the buzzer is disabled. With the HI jumper installed, the buzzer sounds for over voltage. With the low jumper installed, the buzzer sounds for under voltage.
  • Blown Fuse LED: A red LED is located at the base of each fuse clip. If a load is connected, and a fuse is blown (open), then its LED will light.
  • Applications: IPC-610 process
  • Dimensions: 9 x 3 x 1.5 inches overall
  • Mounting Holes: For #8 Hardware, Four holes at 1.75 x 8. 563 inches rectangle
http://www.powerwerx.com/_images/products/PRO-4008-HV2_xlrg.jpgPowerpole Power Distribution
Description

Before Installation

The RIGrunner is ready for installation with the de-fault settings for the "audible alert" (buzzer). The buzzer alerts the user that the voltage is out of normal range, either too high or too low. The user may wish to remove or change the buzzer operation for too high or too low only.

To change the buzzer, simply remove the four sheet metal screws on the side, take the cover off. Then remove either the HI, the LO or both jumpers. They are small blue shorting blocks located at the lower right side of the circuit board.

Note that the four sheet metal screws distort the bottom plate’s holes, thereby creating a burr and making it difficult to remove the cover. If needed, a small screw driver can be wedged into either end to easily pry off the cover.

Replace the cover and fasten together with the four screws. Do not over tighten because the aluminum can be stripped.

Mounting

Pick a location that is central to the equipment it is powering. If possible, locate the power source close to the RIGrunner as well. Every wire has resistance so it makes good sense to keep the wire runs as short as needed.

Locate the RIGrunner in a cool dry place with reasonable ventilation. Do not put it on top of equipment that gets hot. Do not place it on the floor where it could get wet. The unit should be mounted securely to equipment, or screwed down using the two holes in the mounting tabs.

Connecting Equipment

Powerpoles should be placed on all equipment. VIOLET is for plus, and BLACK is for minus. Remember, Powerpoles are genderless; the same connector works on both the supply and the load. They are unipolar if assembled correctly.

Powerpoles can be installed by soldering or crimping. For detailed Powerpole installation tips see our Powerpole General Assembly Instructions.

The only thing you ABSOLUTELY MUST DO is to make sure you assemble the pairs correctly. They must be assembled according to the standard used in the RIGrunner. DO NOT EVER PLUG ANYTHING IN unless you are CERTAIN you have the BLACK connected to minus, and the VIOLET connected to plus. CHECK THIS TWICE. Make sure that your wires plug into the RIGrunner correctly…VIOLET to VIOLET and BLACK to BLACK.

Plug your equipment into the RIGrunner starting with the highest power on the left position and the lower power drain units to the right. You may hook up as many as eight items so long as the total drain does not exceed 40 amperes.

Fuses

This RIGrunner comes supplied with a 40 ampere input fuse, 3 25 A, 2 10A, 1 5A, and 2 1A fuses. It may be ordered with other fuse values. If different fuse values are recommended for the equipment, they may be installed. Note that the total current cannot exceed 40 Amperes. Any ATC/ATO automotive blade fuse or blade circuit breaker may be used.

Note that each fuse position has a LED blown fuse indicator that will conveniently light up if a fuse is blown. There must be power to the RIGrunner and a device plugged into the circuit that has the blown fuse in order for the LED to light.

Voltage Comparator and Audible Alert

The RIGrunner has a precision expanded scale voltage comparator display, with audible alert. There are three LEDs that show Red for over voltage, Green for nominal voltage, and Yellow for under voltage.

This special model operates at a nominal voltage of 55.2 Vdc. This is the fully charged "float" voltage for two AGM or GEL type sealed lead acid batteries. The Green LED that shows that the voltage is between 46 and 60 Vdc. If the voltage is more than 60 Vdc the red LED lights. If the voltage is less than 46 Vdc the Yellow LED lights. If the voltage is under 36 Vdc, then all LEDs are off.

Buzzer

The RIGrunner includes an audible alert buzzer that can sound whenever the Red or Yellow LEDs light.

The buzzer is activated by installing jumpers on the pc card. If the LO jumper is installed, the buzzer will sound whenever the Yellow LED lights. If the HI jumper is installed, the buzzer will sound whenever the Red LED lights. Both jumpers may be installed so the buzzer will sound whenever either the Red or Yellow LED lights.

Note that the RIGrunner comes with both jumpers installed. Please see the "before installation" paragraph to change the buzzer settings.