| Doc Wattson Meter | | Parameter | Range | Resolution | Accuracy (worst-case) | | Voltage | 0-60 Volts * | 0.01 V | ± (1% + 0.035) | | Current | 0-100 Amps *** | 0.01 A | ± (2% + 0.06) | | Power | 0-6554 Watts | 0.1 W | | | Charge | 0-6554 Amp hours | 0.1 Ah | | | Energy | 0-650 Kilo Watthours | 0.01 KWh (10 Wh) | | Increased measurement range compared to Watt's Up Meter shown in bold type. But only measures seven DC values with less resolution: - Amp-Hours: (0 - 6554)
- Kilo Watt-hours: (0 - 650)
- Amps: (0-100 peak)
- Watts: (0 - 6554)
- Peak Amps & minimum Voltage ("sags")
Works with 12, 24, 36 or 48 volt batteries up to 60 V. Lead acid, SLA, Gel Cell, and other battery types are all compatible. * Using auxiliary power/battery input. Minimum is ~4.0 V without it. *** 50 Amps continuous. Derate for wire temperatures above 70 Deg C. | | Watt's Up Meter | | Parameter | Range | Resolution | Accuracy (worst-case) | | Voltage | 0-60 Volts * | 0.01 V | ± (1% + 0.035) | | Current | 0-100 Amps *** | 0.01 A | ± (2% + 0.06) | | Power | 0-6554 Watts | 0.1 W | | | Charge | 0-65 Amp hours** | 0.001 Ah | | | Energy | 0-6554 Watthours** | 0.1 Wh | | Measures up to eight DC values with much higher precision. - Amp-Hours: (0 - 65)
- Watt-hours: (0 - 6554)
- Amps: (0-100 peak)
- Watts: (0 - 6554)
- Peak Amps & peak Watts
- Minimum voltage ("sags")
- Voltage: (0 - 60)
Works with 12, 24, 36 or 48 volt batteries up to 60 V. Lead acid, SLA, Gel Cell, and other battery types are all compatible. * Using auxiliary power/battery input. Minimum is ~4.0 V without it. ** Much higher at reduced resolution. *** 50 Amps continuous, 3-wire connection. Derate for wire temperatures next to case above 70 Deg C. |